Contributors: 15
Author Tokens Token Proportion Commits Commit Proportion
Rui Zhang 447 48.96% 1 5.00%
Viresh Kumar 159 17.42% 1 5.00%
Len Brown 102 11.17% 3 15.00%
Andi Kleen 71 7.78% 1 5.00%
Rafael J. Wysocki 53 5.81% 3 15.00%
Colin Ian King 40 4.38% 1 5.00%
Matthew Garrett 16 1.75% 1 5.00%
Mike Travis 11 1.20% 1 5.00%
Frans Pop 4 0.44% 1 5.00%
Thomas Renninger 3 0.33% 2 10.00%
Thomas Gleixner 2 0.22% 1 5.00%
Al Stone 2 0.22% 1 5.00%
Vasiliy Kulikov 1 0.11% 1 5.00%
Linus Torvalds 1 0.11% 1 5.00%
Lv Zheng 1 0.11% 1 5.00%
Total 913 20


// SPDX-License-Identifier: GPL-2.0-or-later
/*
 * processor_thermal.c - Passive cooling submodule of the ACPI processor driver
 *
 *  Copyright (C) 2001, 2002 Andy Grover <andrew.grover@intel.com>
 *  Copyright (C) 2001, 2002 Paul Diefenbaugh <paul.s.diefenbaugh@intel.com>
 *  Copyright (C) 2004       Dominik Brodowski <linux@brodo.de>
 *  Copyright (C) 2004  Anil S Keshavamurthy <anil.s.keshavamurthy@intel.com>
 *  			- Added processor hotplug support
 */

#include <linux/kernel.h>
#include <linux/module.h>
#include <linux/init.h>
#include <linux/cpufreq.h>
#include <linux/acpi.h>
#include <acpi/processor.h>
#include <linux/uaccess.h>

#define PREFIX "ACPI: "

#define ACPI_PROCESSOR_CLASS            "processor"
#define _COMPONENT              ACPI_PROCESSOR_COMPONENT
ACPI_MODULE_NAME("processor_thermal");

#ifdef CONFIG_CPU_FREQ

/* If a passive cooling situation is detected, primarily CPUfreq is used, as it
 * offers (in most cases) voltage scaling in addition to frequency scaling, and
 * thus a cubic (instead of linear) reduction of energy. Also, we allow for
 * _any_ cpufreq driver and not only the acpi-cpufreq driver.
 */

#define CPUFREQ_THERMAL_MIN_STEP 0
#define CPUFREQ_THERMAL_MAX_STEP 3

static DEFINE_PER_CPU(unsigned int, cpufreq_thermal_reduction_pctg);

#define reduction_pctg(cpu) \
	per_cpu(cpufreq_thermal_reduction_pctg, phys_package_first_cpu(cpu))

/*
 * Emulate "per package data" using per cpu data (which should really be
 * provided elsewhere)
 *
 * Note we can lose a CPU on cpu hotunplug, in this case we forget the state
 * temporarily. Fortunately that's not a big issue here (I hope)
 */
static int phys_package_first_cpu(int cpu)
{
	int i;
	int id = topology_physical_package_id(cpu);

	for_each_online_cpu(i)
		if (topology_physical_package_id(i) == id)
			return i;
	return 0;
}

static int cpu_has_cpufreq(unsigned int cpu)
{
	struct cpufreq_policy policy;
	if (!acpi_processor_cpufreq_init || cpufreq_get_policy(&policy, cpu))
		return 0;
	return 1;
}

static int cpufreq_get_max_state(unsigned int cpu)
{
	if (!cpu_has_cpufreq(cpu))
		return 0;

	return CPUFREQ_THERMAL_MAX_STEP;
}

static int cpufreq_get_cur_state(unsigned int cpu)
{
	if (!cpu_has_cpufreq(cpu))
		return 0;

	return reduction_pctg(cpu);
}

static int cpufreq_set_cur_state(unsigned int cpu, int state)
{
	struct cpufreq_policy *policy;
	struct acpi_processor *pr;
	unsigned long max_freq;
	int i, ret;

	if (!cpu_has_cpufreq(cpu))
		return 0;

	reduction_pctg(cpu) = state;

	/*
	 * Update all the CPUs in the same package because they all
	 * contribute to the temperature and often share the same
	 * frequency.
	 */
	for_each_online_cpu(i) {
		if (topology_physical_package_id(i) !=
		    topology_physical_package_id(cpu))
			continue;

		pr = per_cpu(processors, i);

		if (unlikely(!freq_qos_request_active(&pr->thermal_req)))
			continue;

		policy = cpufreq_cpu_get(i);
		if (!policy)
			return -EINVAL;

		max_freq = (policy->cpuinfo.max_freq * (100 - reduction_pctg(i) * 20)) / 100;

		cpufreq_cpu_put(policy);

		ret = freq_qos_update_request(&pr->thermal_req, max_freq);
		if (ret < 0) {
			pr_warn("Failed to update thermal freq constraint: CPU%d (%d)\n",
				pr->id, ret);
		}
	}
	return 0;
}

void acpi_thermal_cpufreq_init(struct cpufreq_policy *policy)
{
	unsigned int cpu;

	for_each_cpu(cpu, policy->related_cpus) {
		struct acpi_processor *pr = per_cpu(processors, cpu);
		int ret;

		if (!pr)
			continue;

		ret = freq_qos_add_request(&policy->constraints,
					   &pr->thermal_req,
					   FREQ_QOS_MAX, INT_MAX);
		if (ret < 0)
			pr_err("Failed to add freq constraint for CPU%d (%d)\n",
			       cpu, ret);
	}
}

void acpi_thermal_cpufreq_exit(struct cpufreq_policy *policy)
{
	unsigned int cpu;

	for_each_cpu(cpu, policy->related_cpus) {
		struct acpi_processor *pr = per_cpu(processors, policy->cpu);

		if (pr)
			freq_qos_remove_request(&pr->thermal_req);
	}
}
#else				/* ! CONFIG_CPU_FREQ */
static int cpufreq_get_max_state(unsigned int cpu)
{
	return 0;
}

static int cpufreq_get_cur_state(unsigned int cpu)
{
	return 0;
}

static int cpufreq_set_cur_state(unsigned int cpu, int state)
{
	return 0;
}

#endif

/* thermal cooling device callbacks */
static int acpi_processor_max_state(struct acpi_processor *pr)
{
	int max_state = 0;

	/*
	 * There exists four states according to
	 * cpufreq_thermal_reduction_pctg. 0, 1, 2, 3
	 */
	max_state += cpufreq_get_max_state(pr->id);
	if (pr->flags.throttling)
		max_state += (pr->throttling.state_count -1);

	return max_state;
}
static int
processor_get_max_state(struct thermal_cooling_device *cdev,
			unsigned long *state)
{
	struct acpi_device *device = cdev->devdata;
	struct acpi_processor *pr;

	if (!device)
		return -EINVAL;

	pr = acpi_driver_data(device);
	if (!pr)
		return -EINVAL;

	*state = acpi_processor_max_state(pr);
	return 0;
}

static int
processor_get_cur_state(struct thermal_cooling_device *cdev,
			unsigned long *cur_state)
{
	struct acpi_device *device = cdev->devdata;
	struct acpi_processor *pr;

	if (!device)
		return -EINVAL;

	pr = acpi_driver_data(device);
	if (!pr)
		return -EINVAL;

	*cur_state = cpufreq_get_cur_state(pr->id);
	if (pr->flags.throttling)
		*cur_state += pr->throttling.state;
	return 0;
}

static int
processor_set_cur_state(struct thermal_cooling_device *cdev,
			unsigned long state)
{
	struct acpi_device *device = cdev->devdata;
	struct acpi_processor *pr;
	int result = 0;
	int max_pstate;

	if (!device)
		return -EINVAL;

	pr = acpi_driver_data(device);
	if (!pr)
		return -EINVAL;

	max_pstate = cpufreq_get_max_state(pr->id);

	if (state > acpi_processor_max_state(pr))
		return -EINVAL;

	if (state <= max_pstate) {
		if (pr->flags.throttling && pr->throttling.state)
			result = acpi_processor_set_throttling(pr, 0, false);
		cpufreq_set_cur_state(pr->id, state);
	} else {
		cpufreq_set_cur_state(pr->id, max_pstate);
		result = acpi_processor_set_throttling(pr,
				state - max_pstate, false);
	}
	return result;
}

const struct thermal_cooling_device_ops processor_cooling_ops = {
	.get_max_state = processor_get_max_state,
	.get_cur_state = processor_get_cur_state,
	.set_cur_state = processor_set_cur_state,
};